Scroll image to enlarge

HFUC5-25C(DC Coil)

Industry IEC Contactors(DC Coil)

HFUC5-C series

We are here to help! Contact us if you have an inquiry or question.


Certificates:

Product Characteristics

Optimized structure, compatible with other industrial contactors
Optimized materials, excellent resistance to abnormal heat
Optimized arc extinguishing system, better arc extinguishing effect for breaking load current
Long electric endurance under heavy load (AC-4 utilization category).
Abundant auxiliary contact blocks, can be freely combined 
Suitable for harsh environments.

Technical Parameters

Main 
Product SeriesHFUC5
Product or Component TypeContactor
Device short name HFUC5-25
Contactor application

Motor control 

Resistive load

Utilisation category

AC-3

AC-4

AC-1

Poles description3P
[Ue] Rated operational voltage Power circuit: ≤ 690 V AC 50/60Hz
[Ie] Rated operational current25 A (at ≤60 °C) at ≤ 400 V AC AC-3 for power circuit
40 A (at ≤60 °C) at ≤ 690 V AC AC-1 for power circuit

[Us] Control circuit voltage 

(DC Coil)

Voltage: 12   24   36    48   60    72    110   125   220   250
Code   :  JD    BD  CD   ED    ND   SD    FD    GD   MD   UD

[Us] Control circuit voltage 

(DC Coil – Low Consumption)

Voltage: 12   24   48   110  220   250
Code   :   JL   BL    EL   FL   ML    UL
Complementary 
Motor power kW

5.5 kW at 220/230 V AC 50/60 Hz (AC-3)

11 kW at 380/400 V AC 50/60 Hz (AC-3)

15 kW at 660/690 V AC 50/60 Hz (AC-3)

Motor power hp

2 hp at 110…120 V AC 50/60 Hz for 1 phase motors

3 hp at 200…208 V AC 50/60 Hz for 1 phase motors

3 hp at 220…240 V AC 50/60 Hz for 1 phase motors

7.5 hp at 200…208 V AC 50/60 Hz for 3 phases motors

7.5 hp at 220…240 V AC 50/60 Hz for 3 phases motors

15 hp at 440…480 V AC 50/60 Hz for 3 phases motors

20 hp at 550…600 V AC 50/60 Hz for 3 phases motors

Pole contact composition3 NO
[Ith] Conventional free air thermal current 

40 A (at ≤60 °C) for power circuit

10 A (at ≤60 °C) for signalling circuit

[Icw] Rated short-time withstand current 

240 A ≤40 °C - 10 s for power circuit

380 A ≤40 °C - 1 s for power circuit

50 A ≤40 °C - 10 min for power circuit

120 A ≤40 °C - 1 min for power circuit

Associated fuse rating

10 A gG for signalling circuit conforming to IEC 60947-5-1

40 A gG at ≤ 690 V coordination type 2 for power circuit

Average impedance2 mΩ - Ith 50 Hz for power circuit
[Ui] Rated insulation voltage 

Power circuit: 690 V conforming to IEC 60947-4-1

Power circuit: 600 V UL Certified

Signalling circuit: 690 V conforming to IEC 60947-5-1

Signalling circuit: 600 V UL Certified

Overvoltage category III
Pollution degree3
[Uimp] Rated impulse withstand voltage 6 kV conforming to IEC 60947
Mechanical durability10 M cycles
Electrical durability

1.0 M cycles 25 A AC-3 at Ue ≤ 400 V for DC Coil

0.9 M cycles 25 A AC-3 at Ue ≤ 400 V for DC Coil-Low Consumption

Control circuit typeDC
Coil technologyWithout built-in suppressor module
Control circuit voltage limits

0.8...1.1 Us (-40…+60 °C): operational for DC Coil

0.1...0.6 Us (-40…+60 °C): drop-out for DC Coil

Inrush power in W7W   (at 25 °C)  for DC Coil
Hold-in power consumption in W7W   (at 25 °C)  for DC Coil
Control circuit voltage limits

0.8...1.25 Us (-40…60 °C): operational for DC Coil-Low Consumption

0.1...0.3 Us (-40…60 °C): drop-out for DC Coil-Low Consumption

Inrush power in W3.5W   (at 25 °C)  for DC Coil-Low Consumption
Hold-in power consumption in W3.5W   (at 25 °C)  for DC Coil-Low Consumption
Operating time

Power circuit: 52...72 ms closing, 10...20 ms opening

Signalling circuit (NO): 52...72 ms closing, 10...20 ms opening

Signalling circuit (NC): 44...68 ms opening, 10...30 ms closing

Maximum operating rate

Electrical: 600 cycs/h

Mechanical: 3600 cycs/h 

Connections - terminals

Power circuit: screw clamp terminals 1 2.5…10 mm² (AWG 14…8)- cable stiffness: flexible without cable end

Power circuit: screw clamp terminals 2 2.5…10 mm² (AWG 14…8) - cable stiffness: flexible without cable end

Power circuit: screw clamp terminals 1 1.5…10 mm² (AWG 16…8) - cable stiffness: flexible with cable end

Power circuit: screw clamp terminals 2 1.5…6 mm² (AWG 16…10) - cable stiffness: flexible with cable end

Power circuit: screw clamp terminals 1 1.5…10 mm² (AWG 16…8) - cable stiffness: solid without cable end

Power circuit: screw clamp terminals 2 2.5…10 mm² (AWG 14…8) - cable stiffness: solid without cable end

Control circuit: screw clamp terminals 1 1…4 mm² (AWG 18…12) - cable stiffness: flexible without cable end

Control circuit: screw clamp terminals 2 1…4 mm² (AWG 18…12) - cable stiffness: flexible without cable end

Control circuit: screw clamp terminals 1 1…4 mm² (AWG 18…12) - cable stiffness: flexible with cable end

Control circuit: screw clamp terminals 2 1…2.5 mm² (AWG 18…14) - cable stiffness: flexible with cable end

Control circuit: screw clamp terminals 1 1…4 mm² (AWG 18…12) - cable stiffness: solid without cable end

Control circuit: screw clamp terminals 2 1…4 mm² (AWG 18…12)- cable stiffness: solid without cable end

Tightening torque

Power circuit: 22 lb.in(2.5 N·m)- on screw clamp terminals - with screwdriver flat Ø 6 mm

Power circuit: 22 lb.in(2.5 N·m)- on screw clamp terminals - with screwdriver Philips No 2

Control circuit: 11 lb.in(1.2 N·m)- on screw clamp terminals - with screwdriver flat Ø 6 mm

Control circuit: 11 lb.in(1.2 N·m)- on screw clamp terminals - with screwdriver Philips No 2

Auxiliary contact composition1NO1NC,2NO2NC,other combinations can be customized
Minimum switching capacity

24 V,0.1A for C type signalling circuit

17V,5mA for CS type signalling circuit

Insulation resistance> 10 MΩ for signalling circuit
Mounting support

Screw

35mm DIN Rail

Environment 
Standards

GB / T 14048.4, GB/T 14048.5,IEC 60947-4-1, IEC 60947-5-1

UL 60947-4-1, UL 60947-5-1,CSA C22.2 No. 60947-4-1, CSA C22.2 No. 60947-5-1

EN 60947-4-1 (VDE 0660 Teil 102), EN 60947-5-1 (VDE 0660 Teil 200)

BS EN 60947-4-1, BS EN 60947-5-1

Product certificationsCCC,UL(cULus Listed) ,VDE,CE,UKCA
IP degree of protectionIP20 front face conforming to IEC 60529

Permissible ambient air

temperature around the device

-40…+60 °C for normal operating

+60…+70 °C with derating (for operation in the range of Us...1.1Us)

Storage: -60…+80 °C

Operating altitude0...3000 m without derating
Fire resistanceCurrent-carrying parts:850 °C conforming to IEC 60695-2-11
Height92.5 mm
Width45 mm 
Depth107 mm
Net Weight0.62 kg
Packing Units 
Unit type of package 11 box
Number of Units in Package 11 pcs
Package 1 height 11.7cm
Package 1 width 5.2 cm
Package 1 length 9.7 cm
Package 1 weight 0.68 kg
Unit type of package 21 carton
Number of Units in Package 230 pcs
Package 2 height 27.4 cm
Package 2 width 29.3 cm
Package 2 length 33.3 cm
Package 2 weight 20.70 kg
Offer Sustainability 
REACH Regulation Conforming
EU RoHS directive Conforming
Mercury free Yes
China RoHS Regulation Conforming
RoHS exemption information Yes 
Contractual warranty 
Warranty18 months

Dimensions

HFUC5-25~38 (3P, DC coil)  

AC contactor:

Interlock contactor:

Note: The unit is mm. The tolerance for mounting holes: ± 0.5; for other external dimensions: ± 1.5, unless otherwise specified.

Products of the same type
HFUC5-09C(DC Coil)

Industry IEC Contactors(DC Coil)

HFUC5-12C(DC Coil)

Industry IEC Contactors(DC Coil)

HFUC5-18C(DC Coil)

Industry IEC Contactors(DC Coil)

HFUC5-25C(DC Coil)

Industry IEC Contactors(DC Coil)

HFUC5-32C(DC Coil)

Industry IEC Contactors(DC Coil)

HFUC5-38C_(DC Coil)

Industry IEC Contactors(DC Coil)